If you are intending to load a CS1000E Call Server with a gold dongle 
and keycode from the EMS lab keycode generator, 
beware that unless you have a large system type dongle with the system id of 46379 burned onto it, 
the keycode will fail validation. There is no difference in appearance of the large and small dongles, 
they both start with 2000xxxx. 

The large system dongle will work on CS1000E/S/M/T; 
the small system dongle will work only on CS1000S/M/T. 
A small system dongle can however be used in a CS1000E MG. 
A copy of the validation failure message is shown below.

>Validating keycode...
KC Error. "AmKeycodeValidate" returns with error code: 512
"Security Device Modulus error" error

INST0095 Warning: Keycode validation ERROR
INST0090 Unable to install s/w from CDROM to Hard disk
errNo: 0x380003 